You are here: Home > Surgery>Patient monitors >12″ Patient Monitor (Touch Screen)

12″ Patient Monitor (Touch Screen)

12″ Patient Monitor (Touch Screen)

BT-PM9C

12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.

Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.


SP02

Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
Nellcor(TM)  OxiMax(TM) delivers excellent performance,
even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.



ETCO2

Collaborate with Respironics, Plug and Play EtCO2 monitoring.
CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate
and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.


Multi Mounting Solutions



ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                     I, II, III, avR, avL, avF, V
Wave form                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                     I, II, III,
Wavef orm                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm 
Sensitivity                        > 200 (uVp-p) 
Differential Input Impedance       > 5 MΩ

CMRR                   Monitor > 105 dB 
                                   Operation > 105 dB 
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV 
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi. 
ECG Signal Range                   ±8 m V ( Vp-p ) 

Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available


Respiration

Method                           Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range          200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm 
                                    Neo/Ped 0 ~ 150 Brpm 
                                    Resolution 1 Brpm 
                                    Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S
 




NIBP 

Method                            Oscillometric
Mode                              Manual, Auto, STAT                        
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range          40 ~ 240 bpm
Alarm Type                 SYS, DIA, MEAN

Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg 
                                    DIA 10 ~ 215 mmHg 
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg 
                                    DIA 10 ~ 150 mmHg 
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg 
                                    DIA 10 ~ 100 mmHg 
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg 
                                 Pediatric Mode 240±3 mmHg 
                                 Neonatal Mode 147±3 mmHg

SpO2
Measuring Range                  0 ~ 100 % 
Alarm Range                      0 ~ 100 % 
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec. 
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm
                                   


TEMP

Channe                          2
Measuring and Alarm Range 0 ~ 50 ℃
Resolution                      0.1 ℃
Accuracy                ±0.2 ℃
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.


IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg 
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg 


Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω

Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval        about 1 secretary

 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder