Anesthesia Machine

Anesthesia Machine, 2 small vaporizers

BT-2000J1B

TECHNIQUES SPECIFICATIONS
Physical specifications
Screen: LED Display Screen
Suitable Adult & Child
Mode: pneumatically powered and electrically controlled system
Working Mode: Closed; Semi-Closed; Semi-Open
Circuit Breathing circuit integrated standards
Tube: 2 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Safty NO2 Automaticlly Cutting while  oxygen deficiency
Drawer unit Two drawer totally extractable
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.
safety valve <12.5 kPa
Respiratory Rate 4~40bpm
Flow meter O2:0.1~10L/Min,  N2O:0.1~10L/Min
oxygen concentration in the mixed gas N2O/O2 > 21%
Oxygen Flush: 25~75 L/min
Maximum error of the pressure testing device not exceed ± (4% of the full scale reading + 8% of the actual reading)
modes of ventilation A/C,IPPV, SIPPV, MANUAL
I/E Ratio: 1:1.5; 1:2.0;1:2.5; 1:3
Tidal Volume 0~1500ML
Controlled ventilation and assisted ventilation switching time 6s
Maximum safety pressure: ≤ 12.5 kPa
Pressure limit range: 0 ~ 6.0  kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicating upper alarm: 50 to 2000ml,lower alarm: 0~1800ml
Power Supply Alarm "Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s"
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Air source requirement: Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Configuration:
Vaporizer Enflurane/ Isoflurane(Option: Halothane)
Storage
Ambient temperature: -15oC?~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Power
Power supply alarm Audible and visual
Battery Power Typical 30 mins?+, upto180mins
lead-acid battery with a rated
output voltage of DC 12V
It should be charged at an interval no longer than 12h.