Categories
- 0086-512-58697986
- [email protected]
- bestrantech
- 0086-13862268429
High Frequency Mobile Digital C-arm system (Cone Beam CT)
BT-XC10 High Frequency Mobile Digital C-arm system (Cone Beam CT)
I. Application
This machine is widely applied in surgical department, orthopedic surgery, urinary surgery, Spinal surgery, abdominal surgery, Pain Management, Cardiology, Gastroenterology dept., gynae and operating room etc.
II. Configuration
No. |
Item |
Quantity |
1 |
4-Dimensional Motor driven and Isocenter C-arm mainframe |
1 |
2 |
High frequency &voltage X-ray generator and High Frequency inverter power supply |
1 |
3 |
Toshiba 9" three field of view image intensifier |
1 |
4 |
Medical MEGA pixels digital camera system |
1 |
5 |
Digital image Processing System |
1 |
6 |
19' MEGA pixels high definition Medical LCD Monitor |
2 |
7 |
Imported dense grain grids |
1 |
8 |
Electrical adjustable collimator |
1 |
9 |
Human Graphic LCD Touch Screen |
1 |
10 |
Hand controller for parameters |
1 |
11 |
Hand controller for mechanical movement |
1 |
12 |
Foot Brake |
2 |
13 |
3D positioning system |
1 |
14 |
Image transport and processing software |
1 |
15 |
Remote maintenance system |
1 |
III. Specification
Category |
Item |
Main Contents |
Electrical Performance |
X-ray Generator |
Output Power: 5.0kW Inverter Frequency: 60kHz |
Continuous Fluoroscopy (Automatic/ Manual) |
Tube Voltage: 40kV~125kV continuous adjustment |
|
Tube Current:0.3mA~4mA continuous adjustment |
||
Pulse Fluoroscopy |
Tube Voltage:40kV~125kV continuous adjustment Tube Current:4.1mA~30mA continuous adjustment Pulse Frequency:1-10 frame/s continuous adjustment |
|
C-arm Rotation Sequences Radiography |
Tube Voltage:40kV~125kV continuous adjustment Tube Current:4.1mA~15mA continuous adjustment Number of Sequence Radiography: 100frame |
|
Radiography |
40kV~125kV 100mA 0.01-180mAs |
|
X-ray Tube |
Rotary Anode Focus |
0.3/1.5mm |
Anode Thermal Capacity |
35kJ |
|
Tube Thermal Capacity |
650kJ |
|
Image System |
Image Intensifier |
TOSHIBA 9" image intensifier |
CCD Camera |
Medical Mega-pixels digital CCD camera |
|
Monitor |
19' MEGA pixels high definition Medical LCD Monitor |
|
Digital Image Processing System |
Image acquisition module: Achieve a single frame, sequence image acquisition, ultra-high-speed Ethernet pass - real-time transmission |
|
The image processing module: Images have been collected or stored in the module of image processing: tagging, zoom, measurement, sub- window display, Continuous play. 90 Rotation , horizontal mirror , vertical mirror function |
||
The report module: Modify report templates provide a variety of content, user-friendly report writing, report printing function |
||
Film print module: Follow Dicom Medical film typesetting and printing capabilities |
||
Image 3D Processing: 1) Sequence image reconstruction: Run 3D image reconstruction after the acquisition of sequence data is complete. 2) Image reconstruction time less than 10s. 3) Automatic display of the Cross plane, Coronal plane, Sagittal plane and 3D image 4) 3D display: MIP and VRT |
||
Structure Performance |
Direction Wheel Main Wheel |
Direction wheel 360°rotation Main wheel ±90°rotation |
C-arm |
Motorized rotation around horizontal axis: ±180° |
|
Motorized slip on orbit: 190° |
||
Rotation around vertical axis: ±15 |
||
Motorized forward and backward movement: 200mm |
||
Motorized ascending and descending of pillar: 400mm |
||
SID:1025 mm Open:825 mm Arc depth:810 mm |
||
Remote maintenance system |
1) Equipment failure automatic acquisition and analysis 2) Remote operation guide and troubleshooting 3) Workstation Software automatic upgrade |
|
Power supply |
220V ± 20V, 50Hz ± 1Hz |